Skip to main content
ChemVerify

GHK-Cu

Avellon Peptides · Laboratory: Janoshik Analytical

Record no.
231729
Issued
September 11, 2026
Document
Independent test record

Our rating

100of 100

passed

from 4 lab reports

Endotoxin per milligram, content against the label, purity by HPLC, identity and foreign peptides by LC-MS. A failed gate caps the score regardless of the other axes.

How this sample got here

The vendor was not informed.

  1. Ordered

    September 7, 2026

  2. Received

    September 9, 2026

  3. Sent to lab

    September 9, 2026

  4. Analysed

    September 11, 2026

As labelled

Product name on the label
GHK-Cu
Batch number on the label
Stated quantity
50 mg

Measured values

Endotoxin
below detection limit45 of 45
Content
53.08 mg · +6.2 %30 of 30
Purity
99.686 %25 of 25
LC-MS screening
identity confirmed, no foreign peptides10 of 10

LCMS analysis identified the presence of mannitol, GHK(-Cu), and degradation products. LCMS spectra are attached. No significant contamination detected. Latter peak in TIC is caused by sodium or formate adducts.

Heavy metal
  • AsNot detected
  • CdNot detected
  • PbNot detected
  • HgNot detected

The full record

Scroll horizontally if needed. With a keyboard: focus with Tab, then press ← or →.

MeasurandValueResult
LC-MS screening231731
LC-MS screeningPass
Heavy metal231732
Heavy metal · AsNot detected
Heavy metal · CdNot detected
Heavy metal · PbNot detected
Heavy metal · HgNot detected
Content · Purity231729
Content · GHK-Cu53.08 mg
Content · GHK45.1 mg
Content · Cu7.98 mg
Purity99.686 %
Endotoxin231730
Endotoxin< 1 EU/Vial

Laboratory reports