Skip to main content

CJC-1295 (No DAC)

Avellon Peptides · Laboratory: Janoshik Analytical

ChemVerify bought this CJC-1295 (No DAC) sample from Avellon Peptides as a customer on September 22, 2026; Janoshik Analytical analysed it on October 9, 2026. Rating: 87 of 100, passed.

Record no.
237168
Issued
Document
Independent test record
Original laboratory reports (4)

Our rating

87of 100

passed

from 4 lab reports

Endotoxin per milligram, content against the label, purity by HPLC, identity and foreign peptides by LC-MS. A failed gate caps the score regardless of the other axes.

Test criteria and the ChemVerified seal

How this sample got here

  1. Ordered

  2. Analysed

As labelled

Product name on the label
CJC-1295 no DAC 5mg
Batch number on the label
—
Stated quantity
5 mg

Measured values

Endotoxin
below detection limit45 of 45
Content
5.08 mg · +1.6 %30 of 30
Purity
97.677 %11 of 25
LC-MS screening
identity confirmed, no foreign peptides10 of 10

LCMS analysis identified the presence of mannitol and CJC-1295 (mod GRF 1-29). LCMS spectra are attached. No significant contamination detected.

Heavy metal
  • AsNot detected
  • CdNot detected
  • PbNot detected
  • HgNot detected

The full record

Scroll horizontally if needed. With a keyboard: focus with Tab, then press ← or →.

MeasurandValueResult
Endotoxin237169
Endotoxin< 1 EU/Vial—
LC-MS screening237170
LC-MS screening · CJC-1295 (mod GRF 1-29)—Pass
Content · Purity237168
Content · CJC-1295 (mod GRF 1-29)5.08 mg—
Purity97.677 %—
Heavy metal237171
Heavy metal · As—Not detected
Heavy metal · Cd—Not detected
Heavy metal · Pb—Not detected
Heavy metal · Hg—Not detected

Laboratory reports

These results describe the purchased sample. They do not establish the quality of every batch or product from this vendor.

Sample procurement and funding: The sample underlying this test report was purchased by ChemVerify. ChemVerify bears the costs of sample procurement and laboratory analysis. ChemVerify has a paid commercial relationship with the vendor of the tested sample for seal or listing services.

Cite as: ChemVerify (2026). Test protocol 237168: CJC-1295 (No DAC), Avellon Peptides [Data set]. https://www.chemverify.com/tests/cjc-1295-no-dac-237168

All independent tests

For laboratory research use only. Not for human consumption. Must be 18+.