Retatrutide
Avellon Peptides · Laboratory: Janoshik Analytical
- Record no.
- 231721
- Issued
- September 11, 2026
- Document
- Independent test record
Our rating
passed
from 4 lab reports
Endotoxin per milligram, content against the label, purity by HPLC, identity and foreign peptides by LC-MS. A failed gate caps the score regardless of the other axes.
How this sample got here
The vendor was not informed.
Ordered
September 7, 2026
Received
September 9, 2026
Sent to lab
September 9, 2026
Analysed
September 11, 2026
As labelled
- Product name on the label
- Retatrutide
- Batch number on the label
- —
- Stated quantity
- 20 mg
Measured values
LCMS analysis identified the presence of mannitol, retatrutide, and degradation products. LCMS spectra are attached. No significant contamination detected.
- AsNot detected
- CdNot detected
- PbNot detected
- HgNot detected
The full record
Scroll horizontally if needed. With a keyboard: focus with Tab, then press ← or →.
| Measurand | Value | Unit | Result | Method |
|---|---|---|---|---|
| LC-MS screening231723 | ||||
| LC-MS screening | — | — | Pass | LC-MS |
| Heavy metal231724 | ||||
| Heavy metal · As | — | — | Not detected | — |
| Heavy metal · Cd | — | — | Not detected | — |
| Heavy metal · Pb | — | — | Not detected | — |
| Heavy metal · Hg | — | — | Not detected | — |
| Endotoxin231722 | ||||
| Endotoxin | < 1 EU/Vial | EU/Vial | — | — |
| Content · Purity231721 | ||||
| Content · Retatrutide | 22.57 mg | mg | — | — |
| Purity | 99.706 % | % | — | — |