What do the reported endotoxin values actually mean?
26 published endotoxin results with original sources, units and comparison signs: why a bound is not an exact value and an endotoxin test is not a sterility test.
Published by ChemVerify · Data snapshot: · 2026-11-13.v1
What the data shows
26 of 28 samples have a structured endotoxin result. The 26 result rows contain 12 reported point estimates, 13 upper bounds and 1 lower bound. 2 samples have no structured endotoxin result.
These are selected purchases, including a peptide blend. The counts describe this dated export. They are not a contamination rate for the market, a vendor ranking or a clinical assessment.
How to read the comparison sign
- < 1 EU/Vial
- The reported result is below 1 endotoxin unit per vial. It is not an observed zero and is not an exact value of 1. The comparison sign alone does not establish whether 1 is a detection limit, quantification limit or another reporting boundary.
- > 1,000 EU/Vial
- The reported result exceeds 1,000 endotoxin units per vial. The exact value is not supplied. Replacing it with 1,000 would discard information and understate the result.
- A point estimate
- A value reported without an inequality remains a point estimate from the laboratory. It does not imply zero measurement uncertainty. Consult the original report for the method and any qualification.
We do not replace bounded results with zero, half the boundary or the boundary itself, and do not calculate a mean from those substitutions. We retain EU/Vial as reported; no conversion to EU/mg or EU/mL is made.
A qualification in the original report
Report #221430 also gives 1,204.220 EU/Vial as an estimate. Its comment states that values above 1,000 EU/Vial fall outside the assay’s validated range and that another vial and dilution are needed for an accurate result. The frozen export retains > 1,000 EU/Vial; this analysis does not substitute the additional estimate as a validated point value.
Read the result and qualification in laboratory report #221430Every reported endotoxin observation
One row per structured endotoxin result, in dataset order. The linked laboratory reference is the source of the value. A report can contain more than one result; result rows and samples remain separate counts.
On small screens, scroll the table horizontally.
| Sample / source | Reported result | Original report |
|---|---|---|
| BPC-157 · #231753 | 2.951 EU/Vial | #231754September 11, 2026 |
| BPC-157/TB-500 5mg/5mg · #237179 | 1.219 EU/Vial | #237180October 9, 2026 |
| CJC-1295 no DAC 5mg · #237168 | < 1 EU/Vial | #237169October 9, 2026 |
| Epithalon · #231741 | < 1 EU/Vial | #231742September 11, 2026 |
| GHK-Cu · #231729 | < 1 EU/Vial | #231730September 11, 2026 |
| Ipamorelin 10mg · #237164 | 5.392 EU/Vial | #237165October 9, 2026 |
| KPV · #231725 | < 1 EU/Vial | #231726September 11, 2026 |
| Melanotan 2 · #231749 | 1.559 EU/Vial | #231750September 11, 2026 |
| MOTS-c 10mg · #237156 | < 1 EU/Vial | #237157October 9, 2026 |
| MOTS-c 40mg · #237160 | < 1 EU/Vial | #237161October 9, 2026 |
| BPC-157 10mg · #250578 | 4.135 EU/Vial | #250579November 9, 2026 |
| GHK-Cu 100mg · #250574 | 1.966 EU/Vial | #250575November 9, 2026 |
| Retatrutide 10mg · #250570 | 5.467 EU/Vial | #250571November 9, 2026 |
| Semax 10mg · #250586 | 6.765 EU/Vial | #250587November 9, 2026 |
| TB 500 10mg · #250582 | 1.16 EU/Vial | #250583November 9, 2026 |
| Retatrutide · #217945 | < 1 EU/Vial | #221428September 2, 2026 |
| Retatrutide · #217946 | > 1,000 EU/Vial | #221430September 2, 2026 |
| Retatrutide · #217948 | < 1 EU/Vial | #221434September 2, 2026 |
| Retatrutide · #217949 | < 1 EU/Vial | #221436September 2, 2026 |
| Retatrutide · #231721 | < 1 EU/Vial | #231722September 11, 2026 |
| Selank · #231737 | 1.111 EU/Vial | #231738September 11, 2026 |
| Semax · #231733 | < 1 EU/Vial | #231734September 11, 2026 |
| SS-31 · #231745 | 1.005 EU/Vial | #231746September 11, 2026 |
| TB500 10mg · #237187 | < 1 EU/Vial | #237188October 9, 2026 |
| Tesamorelin 10mg · #237183 | < 1 EU/Vial | #237184October 9, 2026 |
| Thymosin Alpha-1 5mg · #237175 | 1.684 EU/Vial | #237176October 9, 2026 |
No structured endotoxin result
Absence from this export does not establish that the laboratory never tested the sample. Unclassified free-text results are not reassigned by this analysis.
Endotoxin testing and sterility answer different questions
USP describes bacterial endotoxin testing as detecting or quantifying endotoxins from Gram-negative bacteria. Sterility concerns viable microorganisms. An endotoxin value by itself does not establish sterility, and a sterility result by itself does not establish the absence of endotoxin.
The linked USP sources explain the distinction. They do not certify these samples. This report sets no acceptance limit and makes no claim of suitability for human or animal use.
Download and cite this edition
This edition uses a frozen copy of the public dataset. Later results may change the live database without changing this report. JSON preserves the sample, report and measurement fields, including uncertainty where reported.
Source data: CC BY 4.0. Attribute ChemVerify and retain the original laboratory references.
Suggested citation
ChemVerify (2026). What do the reported endotoxin values actually mean? Research & Evidence, 2026-11-13.v1. https://www.chemverify.com/research/endotoxin-results