Does “not detected” mean zero heavy metals?

108 qualitative entries across 27 published heavy-metal reports: what non-detection establishes, which elements are covered and why no concentration is inferred.

Published by ChemVerify · Data snapshot: · 2026-11-13.v1

The short answer

27 of 28 samples have structured heavy-metal results. Across 27 report records, all 108 analyte entries say “not detected”; none contains a numerical concentration or unit. This supports a count of reported non-detections, not a claim of zero metal content.

The recorded elements are arsenic (As), cadmium (Cd), lead (Pb) and mercury (Hg). Each has a “not detected” entry in 27 samples. Four entries per sample are not four independent purchases, and a four-element panel does not cover every metal.

Janoshik: scope of heavy metals analysis

Why “not detected” does not mean zero

Detection depends on the analytical procedure and its detection capability. IUPAC distinguishes a result-specific detection decision from a method’s detection limit. A non-detection alone does not provide a measured zero, a numerical upper bound or a concentration that can be compared with a limit.

IUPAC: detection and quantification capabilities

Read a complete source, including its comments

In original report #231756, arsenic, cadmium and lead appear in the results table. Mercury is recorded as “not detected” in the comments. The export contains all four entries. A reading of the table alone would miss the mercury result. This checked example does not authenticate every report in the dataset.

Original report #231756

All 27 report records

ND = “not detected”, retained as a qualitative result. No concentration, unit or detection limit is supplied by these structured entries. Original reports may contain information beyond the export; follow the source for each sample.

On small screens, scroll the table horizontally.

All 27 report records
Sample / sourceAsCdPbHgOriginal report
BPC-157 · #231753NDNDNDND#231756September 11, 2026
BPC-157/TB-500 5mg/5mg · #237179NDNDNDND#237182October 7, 2026
CJC-1295 no DAC 5mg · #237168NDNDNDND#237171October 7, 2026
Epithalon · #231741NDNDNDND#231744September 11, 2026
GHK-Cu · #231729NDNDNDND#231732September 11, 2026
Ipamorelin 10mg · #237164NDNDNDND#237167October 7, 2026
KPV · #231725NDNDNDND#231728September 11, 2026
L-Carnitine 500mg · #237174NDNDNDND#237174October 7, 2026
Melanotan 2 · #231749NDNDNDND#231752September 11, 2026
MOTS-c 10mg · #237156NDNDNDND#237159October 7, 2026
MOTS-c 40mg · #237160NDNDNDND#237163October 7, 2026
BPC-157 10mg · #250578NDNDNDND#250581November 6, 2026
GHK-Cu 100mg · #250574NDNDNDND#250577November 6, 2026
Retatrutide 10mg · #250570NDNDNDND#250573November 6, 2026
Semax 10mg · #250586NDNDNDND#250589November 6, 2026
TB 500 10mg · #250582NDNDNDND#250585November 6, 2026
Retatrutide · #217945NDNDNDND#221429August 28, 2026
Retatrutide · #217946NDNDNDND#221431August 28, 2026
Retatrutide · #217948NDNDNDND#221435August 28, 2026
Retatrutide · #217949NDNDNDND#221437August 28, 2026
Retatrutide · #231721NDNDNDND#231724September 11, 2026
Selank · #231737NDNDNDND#231740September 11, 2026
Semax · #231733NDNDNDND#231736September 11, 2026
SS-31 · #231745NDNDNDND#231748September 11, 2026
TB500 10mg · #237187NDNDNDND#237190October 7, 2026
Tesamorelin 10mg · #237183NDNDNDND#237186October 7, 2026
Thymosin Alpha-1 5mg · #237175NDNDNDND#237178October 7, 2026

One sample without a classified result

BAC water #241124 has no structured heavy-metal result in this edition. It is excluded from the 27-sample denominator. Absence from the export does not establish that a test was never performed.

BAC water · #241124

What is needed for a numerical comparison?

  • The named element and the sample or batch to which the result applies.
  • A result or reporting bound, its unit and its basis, such as mass per vial or mass per mass of sample.
  • The analytical method and the applicable detection or reporting limit, including the laboratory’s explanation of “not detected”.
  • The scope and basis of any comparison criterion. This report applies no safety threshold and derives no mean concentration or vendor ranking.

Download and cite this edition

This edition uses a frozen copy of the public dataset. Later results may change the live database without changing this report. JSON preserves the sample, report and measurement fields, including uncertainty where reported.

Source data: CC BY 4.0. Attribute ChemVerify and retain the original laboratory references.

Suggested citation

ChemVerify (2026). Does “not detected” mean zero heavy metals? Research & Evidence, 2026-11-13.v1. https://www.chemverify.com/research/heavy-metal-results

Source checksum (SHA-256)451bee625402c1f15b7cf29ea6cbdf46d7bd915631aec9aef0753bca6c470ad8